How to Read a Bar Grating Load Table

How to Read a Bar Grating Load Table

Knowing how to read a bar grating load table helps engineers, contractors and facility managers select grating that can safely support expected loads. These tables show how bearing-bar dimensions, support spans and loading conditions affect performance.

Understanding the information is essential when specifying industrial flooring, walkways, platforms and other load-bearing surfaces.

What Information Does a Bar Grating Load Table Provide?

A load table identifies the structural capabilities of a particular grating configuration. Borden’s technical tables include several important measurements:

  • Bearing-bar size: The depth and thickness of the load-bearing bars.
  • Span: The clear distance between supports, measured along the bearing bars.
  • Uniform load (U): The allowable load distributed evenly across the grating, usually expressed in pounds per square foot (psf).
  • Concentrated load (C): The allowable load applied across the grating width at midspan, expressed in pounds per foot of width.
  • Deflection (D): How far the grating bends under the specified load, measured in inches.

These values help determine whether a particular configuration is appropriate for the intended application.

How Do You Read a Load Table Step by Step?

When learning how to read a bar grating load table, follow these steps:

1. Identify the grating type. Select the correct table for welded, pressure-locked or another construction type.

2. Find the bearing-bar size. Locate the row showing the required bar depth and thickness.

3. Identify the clear span. Find the column corresponding to the unsupported distance between bearing-bar supports.

4. Check the load capacity. Read the uniform or concentrated load value, depending on the application.

5. Review deflection. Confirm that the predicted bending is acceptable for the project.

Always read the manufacturer’s notes and units before interpreting the results.

Why Do Span and Deflection Matter?

As the distance between supports increases, grating generally carries less load and bends more under the same loading conditions.

Deflection is particularly important for pedestrian areas. Borden’s welded grating tables identify recommended maximum spans based on a 1/4-inch deflection limit under a uniform load of 100 psf, representing normal pedestrian traffic.

Other applications may require different deflection limits or engineering calculations.

What Should Canadian Specifiers Watch For?

Load tables typically assume specific materials, support conditions and loading arrangements.

Before making a final selection, consider concentrated equipment loads, moving vehicles, impact, corrosion exposure and applicable building or workplace safety requirements.

A load table is a selection tool, not a substitute for project-specific engineering where required.

Selecting Grating Using Load Tables

Understanding how to read a bar grating load table makes product selection more reliable and helps prevent specification errors.

Explore Borden’s welded grating products and load tables, or contact Borden for assistance with your project.

Quick FAQ

What Does U Mean on a Bar Grating Load Table?

U represents the allowable uniformly distributed load, typically measured in pounds per square foot.

What Is the Difference Between Uniform and Concentrated Loads?

Uniform loads are spread across the grating surface. Concentrated loads act over a smaller area or along a defined line, requiring separate evaluation.

Can I Use the Same Load Table for Different Grating Materials?

No. Load tables must match the specified grating construction, material and dimensions. Different materials can have different structural properties.